CEL-620B1 Enhanced

SKU
CEL-620B1
Class 1
Microphone
Class 2
Microphone
Broadband CEL-620A1 CEL-620A2
Octave Band This Product CEL-620B2

The CEL-620 Series Enhanced has new features including:

  • Time history storage (Selectable from 1s to 30min)
  • Larger memory (999 runs)
  • Voice notes (Up to 33 hours of audio storage)
  • GPS

The CEL-620 Enhanced digital Sound Level meters can be used for the measurement of all workplace noise parameters to comply with workplace noise legislation, e.g. EU, OSHA and ACGIH. Use the CEL-620 Series to carry out occupational noise assessments or machinery noise tests as well as to assist with the selection of hearing protection. Choose a CEL-620 Series model to suit your requirements, either with a Class 1 or Class 2 Microphone for precision, and with or without Octave Band analysis, to aid you in the choice of hearing protection. The CEL-620 is a simple to use meter and data is displayed on the high resolution colour display. Measurement screens are intuitively colour coded according to the mode of operation, i.e. green if a measurement is being taken and red when a run has ended. Data is graphically displayed to give a clearer picture of the noise environment. Calibrate easily on-site with the 120 Series Calibrator to comply with best practice. The instrument also has six selectable setups – four that are pre-defined to legislative standards and two that can be customised so that you get the data you need. Regardless of the setup, the CEL-620 measures and stores ALL parameters, even if not selected and these can be viewed in the software. All runs are date and time stamped and the CEL-620 stores up to 999 runs. The 999 runs can be up to 24 hours each, even with the 1s time history stored. Simply connect your CEL-620 to a PC via the USB connection and the data can be easily reviewed without the need for proprietary software. The instrument has a single large measurement range of 20-140dB meaning that you don’t need to change range. On the CEL-620B, Octave band analysis is shown in real-time in both graphical and tabular format with the dominant frequency highlighted.

  • Noise at work applications
  • Single large measurement range
  • Simple operation
  • Rugged design
  • Selection of hearing protection via HML or Octave (B model) method
  • Calculation of noise exposure
  • Pre-defined and user configurations available
  • Compliant with IEC 61672 Class 1 or 2 and ANSI S1.4

Instruments come complete with a download cable, batteries and field guide and includes the instrument calibration certificate.